产品描述


HAKKO FE-510

HAKKO FE-510イメージ

Available in:

  • Japan
  •  
  •  
  •  
  • Asia
  •  
  • Other Countries
  • RoHS
  • Static eliminator that allows the selection of area intended for static neutralization
  • Locking mechanism maintains angle of eliminator unit
  • Error output signal function is useful to incorporate the unit into line applications


  • Features
  • Packaging List / Specifications
  • Soldering Tip / Nozzle
  • Replacement Parts / Option
  • Maintenance

Features

Choice of two louvers lets you select static elimination area.

Louvers snap on and off for easy handling. Safe design ensures unit cannot be turned on unless louver is attached correctly.

Wide-angle louver

HAKKO FE-510 wide-angle louver

Straight louver

HAKKO FE-510 Straight louver



Locking mechanism maintains angle of eliminator unit

If you've ever found that a static eliminator wasn't working because vibration had shaken it out of alignment, you'll appreciate the FE-510's handy locking mechanism, which eliminates misalignment problems caused by vibrating equipment.

Locking mechanism

Error output signal is useful in built-in applications. This feature can be used to warn the operator when the discharge electrode is dirty or worn.

When used on a desktop, these warnings are provided by indicators.

HAKKO FE-510

Superb ease of maintenance

Discharge electrode can be replaced simply by turning it gently in a clockwise direction.

Superb ease of maintenance

HAKKO 498

HAKKO 498イメージ

Available in:

  • Japan
  •  
  • North America
  •  
  • EU
  •  
  • Asia
  •  
  • Other Countries
  • RoHS
  • Easy-to-use, quick-response tester for wrist strap
  • Connection status of wrist strap can be easily checked



  • Features
  • Packaging List / Specifications
  • Soldering Tip / Nozzle
  • Replacement Parts / Option
  • Maintenance

Features

Can be used any where to quickly and easily check a variety of grounding systems.
Ensures employee safety.
Eliminates product defects caused by static electricity.

How to use HAKKO 498




HAKKO 441B

HAKKO 441Bイメージ

Available in:

  • Japan
  •  
  •  
  •  
  •  
  • RoHS
  • Tester for antistatic shoes that enables the simultaneous check of shoes and human body
  • Resistance range specified by the former JIS T 8103 (prior to the revision) can be also selected with a selector switch



  • Features
  • Packaging List / Specifications
  • Soldering Tip / Nozzle
  • Replacement Parts / Option
  • Maintenance

Features

Tester for antistatic shoes
Both shoes and the human body can be simultaneously tested for static charge 
The judgment based on JIST8103-specified standard values is indicated with a lamp and electronic sound
HAKKO 441B enables to control shoe wear, dirt and service conditions by classifying the JIS T8103 standard range into the following three levels:
Indication Resistance Range* (Ω) Status
108 Ωmode 109 Ωmode
I 1 x 105 to 1 x 106 1 x 105 to 1 x 106 Sole is worn out.
II 1 x 106 to 1 x 107 1 x 106 to 1 x 107 Good
III 1 x 107 to 1 x 108 1 x 107 to 1 x 109 Sole is dirty.
*Reference value

The judging criterion is selectable from two modes: 1×108Ω or 1×109Ω (with the selector switch)
Judgment Resistance Range (Ω) Indicator Buzzer
108Ωmode 109Ωmode
LOW R < 1 x 105 R < 1 x 105 Red lamp OFF
GOOD 1 x 105 >= R >=1 x 108 1 x 105 >= R >=1 x 109 Green lamp ON
HIGH 1 x 10< R 1 x 109 < R Red lamp OFF
   
How to use HAKKO 441B How to use HAKKO 441B
HAKKO 441B is easy to use. Put on antistatic shoes, stand on the test plate, and press the pad. The main unit can be placed on a table or mounted on a wall surface with the accessory mounting base.

Usage/Applications


Does HAKKO 441B affect pacemakers?

A small amount of electric current will flow through the human body when using HAKKO 441B.
Please do not use HAKKO 441B if having a weak heart or heart pacemaker.

img


 Maintenance

When the judgment is LOW, possible causes could be:

  • The shoe sole is worn out;
  • A metal fragment is embedded in the shoe sole; or
  • There is dew condensation inside 441 or 441B.
  • Dew condensation occurs inside the tester if the tester is heated up rapidly because of a sudden temperature change such as moving from a cool place to a hot place in winter.
When the judgment is LOW


When the judgment is HIGH, possible causes could be:

  • Wearing heavy socks;
  • There are problems with the shoes or the shoe sole is dirty;
  • Dry hands; or
  • The cord asse'y is short-circuited or broken.
When the judgment is HIGH

If any of the above conditions don't apply to the case, the product is broken.
Please return it to where you bought it for repair.


HAKKO FG-101

HAKKO FG-101イメージ

Available in:

  • Japan
  •  
  • North America
  •  
  • EU
  • Oceania
  •  
  • Asia
  •  
  • Other Countries
  • LEAD FREE
  • RoHS
  • Soldering iron tester useful for daily maintenance of station type soldering irons
  • Tip temperature, leak voltage and tip-to-ground resistance can be easily measured with high accuracy
  • MAX HOLD Function


Manuals / MSDS / Engineering documents
  • Features
  • Packaging List / Specifications
  • Soldering Tip / Nozzle
  • Replacement Parts / Option
  • Maintenance

Features

One tester for all your soldering iron maintenance needs.
What should you check when doing a daily inspection of your soldering iron?
Grounded soldering irons are maintained by inspecting leak voltage, tip-to ground resistance, and tip temperature.
Grounded soldering irons cannot be maintained by checking insulation resistance. This method was used in the past in order to find out the level of leak current.

 What is 'Leak voltage'?
Leak current is the current that leaks from the tip to a board or device. Leak voltage is a specific measurement of the level of this current. The leakage can adversely affect delicate devices, so it is necessary to check leak voltage on a daily basis.
Leak voltage is the current that leaks from the tip of a soldering iron to a board or device


 What is 'Tip-to-ground resistance'?
Most leak current flows from the tip via the ground wire to the outlet ground terminal, and is prevented from affecting the device. Because of this, tip-to-ground resistance is another important issue that must be checked daily.
It is also important to check tip-to-ground resistance on a daily basis.


 Why is tip temperature important?
As the tip, element cover and other parts oxidize, heat conduction deteriorates and the tip temperature becomes lower. This causes the difficulty of soldering. Therefore, tip temperature should be inspected daily to have better soldering.
Maximun current value mesured with HAKKO FG-101

100V-120V Spec 5A
220V-240V Spec 3A
Note: HAKKO FG-101 is broken when beyond maximum current value is measured. 

In addition to traditional features, the FG-101 comes with two new functions: MAX HOLD and AUTO ZERO.

MAX HOLD Function Constantly displays the maximum temperature
AUTOZERO Function Automatically corrects zero point error of measuring instruments
Traditional Features Lead-free sensor
Measures leak voltage by True Root Mean Square (TRMS)
Highly reliable - Resistant to drift and changes in temperature
* The FG-101 does not come with the Monitor Output function that was included in past models.

 


 MAX HOLD Function
Display Sample of MAX HOLD FunctionWhen the MAX HOLD function is on, the maximum temperature is constantly displayed on the LCD.
If the MAX HOLD button is pressed for a short time (less than 1 second) the maximum temperature is updated. If the button is pressed for a long time (1 second or longer) the MAX HOLD function turns off.
 AUTO ZERO Function
The zero point error of measuring instruments can be corrected by simply pressing the AUTO ZERO button and waiting for the display to return to normal.

Display Sample of AUTO ZERO Function

Usage/Applications

 How to measure the tip temperature, leak voltage and tip to ground resistance


Do not blow hot air (for example, with the HAKKO FR-802, etc.) directly onto the HAKKO FG-101 to measure the temperature.
If the hot air is blown directly onto the tester, the main unit of HAKKO FG-101 itself will be damaged.
Please use the temperature probe for Hot Air Rework System

 
When using the HAKKO FG-101, plug it into the outlet with a grounding terminal.

The HAKKO FG-101 cannot measure the leak voltage and tip to ground resistance of a soldering iron which has no grounding pin.
It can measure the leak voltage and tip to ground resistance of a soldering iron which has a plug with grounding pin.

Bipolar grounding plug (3-pin) |Flat plug (2-pin)


 Differenced in the measurement methods according to tip shapes

For the precise temperature measurement, place the tip on the measuring point on sensor horizontally.




 Guaranteed temperature range with the measurement tolerance of ±3°C

In general, the optimal temperature range for soldering is 300°C to 500°C, and that for SMD rework system is 300°C to 600°C. The tolerance of ±3°C within the optimal temperature range (300°C to 600°C) is assured. For the temperature range other than the above, the tolerance is not guaranteed but usually stays in the range of about ±5°C.


HAKKO FG-100

HAKKO FG-100イメージ

Available in:

  • Japan
  •  
  • North America
  •  
  • EU
  • Oceania
  •  
  • Asia
  •  
  • Other Countries
  • LEAD FREE
  • RoHS
  • Tip thermometer providing reliable temperature control of soldering iron tips
  • Compact design saves your workspace and allows you to easily carry it around
  • Extremely fine sensor with high temperature reactivity is incorporated


  • Features
  • Packaging List / Specifications
  • Soldering Tip / Nozzle
  • Replacement Parts / Option
  • Maintenance

Features

Surely and easily Temperature control
Suitable for Lead-Free Solder
· Good temperature response using a fine CA wire sensor (φ0.2mm)
· Disposable sensor always maintains accurate temperature measurment
(Replace sensor when the measuring point underwent degradation)
· Sensor has the twice service life than conventional ones.
Dimensional Measurement
· Allows you to measure from any desired direction according to tip shape
  Measuring Sample of Thermometer HAKKO FG-100 *Design image only
Auto Shut-Off Function
· If no measurement operation is performed within 3 minutes, the power will be automatically shut off.
MAX HOLD Function
· When the button "MAX HOLD" is pressed, "MAX HOLD" will be displayed and the highest temperature of Iron will be held in the display.
  Display Sample of MAX HOLD Function
Easy-to-read temperature
· Large and clear display
· Digital temperature display make to read it accurately
Compact Size
· Convenient to carry and saves your workspace

Usage/Applications

 Initial display (room temperature) appearing when the power is turned ON

It is not necessary to deduct the room temperature that was displayed when the power was turned ON from the measured temprature. The temperature appearing on the LED display is the actual measured value.



 Guaranteed temperature range with the measurement tolerance of ±3°C

In general, the optimal temperature range for soldering is 300°C to 500°C, and that for SMD rework system is 300°C to 600°C. The tolerance of ±3°C within the optimal temperature range (300°C to 600°C) is assured. For the temperature range other than the above, the tolerance is not guaranteed but usually stays in the range of about ±5°C.


HAKKO FG-450

HAKKO FG-450イメージ

Available in:

  • Japan
  •  
  •  
  •  
  • Asia
  •  
  • Other Countries
  • RoHS
  • Portable static level meter for the measurement of electric potential for films and plastic objects
  • Useful for the check of electric potential measurement in production lines
  • Also suitable for the operation test of static eliminators and static potential check for computers



  • Features
  • Packaging List / Specifications
  • Soldering Tip / Nozzle
  • Replacement Parts / Option
  • Maintenance

Features

Portable Static Level Meter, easily measured anywhere with Rotating Sensor Head.
Rotating Sensor Head enables you to read the measurement value easily at any pointing angle.
? Rotates 180 degree by 45 degree increments
Portable Static Level Meter, easily measured anywhere with Rotating Sensor Head. image
Two modes for measuring electric potential:
? Electric Potential Measurement
Momentary and peak value of static electric potential.
Human body static electric potential, which can be measured hard in general, can be easily measured with Option Charging Level Measurement Plate for Body attached to the unit.
  * Measurement for the charged object.
  * Measurement value can be hold temporarily by pressing Hold Button.
? Ion Balance Measurement for Ionization Equipment HAKKO FE-510 etc.
  * Ion balance of the object cannot be measured.


 
Measurement Example of Electric Potential for Object. image Measurement Example of Ion Balance image Measurement Example of Electric Potential for Body image
Measurement Example of Electric Potential for Object. 
(Resolution: 10V)
Measurement Example of Ion Balance 
(Resolution: 1V)
Measurement Example of Electric Potential for Body 
(Resolution: 10V)
   
The unit of measurement value on display is ‘kV’.
  If the result of measurement is 10V, the value on display shows ‘0.01kV’ in case of static electric potential.
If the result of measurement is 1V, the value on display shows ‘0.001kV’ in case of ion balance.
The distance between the sensor and the charged object should be 30mm.
  Easily adjusts the distance by Red LED mark pointing at the charged object.
The red light Image is projected at about 30mm.
   
Adjusts Zero Point easily with just a single touch of a button.
Battery indicator informs you the replacement timing of battery.
  When the battery charge icon shows one unit left on display, replace the battery.

NOTE If you do not intend to use this device for an extended length of time, remove the battery.






http://www.enfionsh.com